Technical data

Digital laser measure

Zamo

Article number

‎3 603 F72 9..‎

Distance measurement

Measuring rangeA)

0.15–25 m

Measuring accuracyB)

±2.0 mm

General

Operating temperature

–10 °C to +40 °C

Storage temperature

–20 °C to +70 °C

Relative air humidity max.

90 %

Max. altitude

2000 m

Pollution degree according to IEC 61010-1C)

2

Laser class

2

Laser type

635 nm, < 1 mW

Divergence of the laser beam

< 1.5 mrad (full angle)

Automatic switch-off (without measurement) after approx.

5 min

Weight according to EPTA-Procedure 01:2014

0.08 kg

Dimensions (L x W x H)

104 × 38 × 23 mm

Batteries

2 x 1.2 V HR03 (AAA)
2 x 1.5 V LR03 (AAA)

Battery life
(HR03, continuous measurement)D)

> 3 h

Battery charging time (HR03, 800 mAh)D)

< 4 h

Power supply

Output voltage

5.0 V

Output current

> 500 mA

Recommended power supply

‎2 609 120 713 (EU)‎

‎2 609 120 718 (UK)‎

‎2 609 120 717 (AU)‎

USB Type-C® cable

Recommended USB Type-C® cable

‎1 600 A01 L6H‎

A)

When measuring from rear edge. In unfavourable conditions such as very strong lighting, a temperature greatly deviating from 20 °C or a poorly reflecting surface, the measuring range can be restricted.

B)

This applies for high reflectivity of the target (e.g. a wall painted white), weak background lighting and a 20 °C operating temperature; a deviation of ±0.05 mm/m must additionally be factored in.In unfavourable conditions such as strong lighting, great heights or a poorly reflecting surface, and at a temperature of 20 °C, the deviation can be ±4 mm; a deviation of ±0.15 mm/m must additionally be factored in

C)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

D)

At an operating temperature of 20 °C

The serial number (11) on the type plate is used to clearly identify your measuring tool.

Adapter

 

Operating temperature

–10 °C to +40 °C

Storage temperature

–20 °C to +70 °C

Relative air humidity max.

90 %

Pollution degree according to IEC 61010-1A)

2

Laser line adapter

Article number

‎1 600 A02 PZ7‎

Width of laser lineB) at a 2 m distance

≤ 2.0 m

Length of the laser lineB) at a 2 m distance

≥ 1 m

Measuring accuracyC)

±1.0 mm/m

Opening angle

≥ 28°

Angle for fine adjustment

±10°

Weight according to EPTA-Procedure 01:2014

0.02 kg

Dimensions

38 x 40.5 x 22.3 mm

Tape adapter

Article number

‎1 600 A02 PZ8‎

Measuring accuracyC)

±1.0 mm/m

Measuring range

0.005 m to 1.5 m

Weight according to EPTA-Procedure 01:2014

0.03 kg

Dimensions

38 x 33.5 x 22.3 mm

Wheel adapter

Article number

‎1 600 A02 PZ9‎

Measuring accuracyC)

±5.0 mm/m

Measuring range

25 m

Weight according to EPTA-Procedure 01:2014

0.02 kg

Dimensions

38 x 48 x 22.3 mm

A)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

B)

depending on surface characteristics and ambient conditions

C)

At an operating temperature of 20 °C