Rectifying faults

Problem

Corrective measure

Suction turbine will not switch on.

  • Check the mains cable, mains plug, fuse, socket and fill level sensors (14).
  • Set the mode selector switch (4) to the "On" symbol or switch on the power tool plugged into the plug socket (5).

The suction turbine switches off.

  • Empty the container (9).

The suction turbine will not switch on again after the container has been emptied.

  • Switch the dust extractor off and wait 5 seconds before switching it back on.
  • Clean the fill level sensors (14) and the space between the fill level sensors (14) using a brush.

The suction power is decreasing.

  • Remove any blockages from the vacuum nozzle, suction tube, vacuum hose (8) or pleated filter (12).
  • Change the dust bag (11).
  • Place the top part of the dust extractor (3) on correctly and close the catches (10).
  • Change the pleated filter (12).

Dust is escaping during extraction

  • Check that the pleated filter (12) has been fitted correctly.
  • Change the pleated filter (12).

Automatic switch-off (wet extraction) is not working.

  • Clean the fill level sensors (14) and the space between the fill level sensors (14) using a brush.

Automatic switch-off will not work in the presence of non-conductive liquids or foaming.

  • Check the fill level regularly.